Complete version of this page: Drinking water thermoelectric cooler for passenger in railroad cars
Drinking water thermoelectric cooler for passenger in railroad cars
Thermoelectric water cooler (TWC) supplies passengers in railroad cars with cooled purified drinking water.
TWC is mounted in conductor’s compartment. Previously boiled water enters TWS through the fine filter (particle size < 5 micron) and after cooling and bactericide treatment under ultraviolet lamp comes into dispenser.
| N N |
Characteristic |
Value |
| 1. |
Type of cooler |
Thermoelectric |
| 2. |
Mode of operation |
Continuous |
| 3. |
Tank volume of drinking water |
4.6 litre |
| 4. |
Temperature of coming water |
≤ + 900C |
| 5. |
Temperature of cooled water |
+ 15 ± 20C |
| 6. |
Water cooling time for the first charge |
≤180 min |
| 7. |
Power consumption at ambient temperature ? + 250C |
300 Watt |
| 8. |
Maximum power consumption |
500 Watt |
| 9. |
Output of cooled water |
≥ 80 litre/day |
| 10. |
Dimensions |
420x365x470 mm |
| 11. |
Weight without water |
22.5 kg |
|  |